胡盛勇,王国力,赖盛景,侯强,梁天锡.多层阻尼复合板常温贮存5年性能研究[J].装备环境工程,2017,14(1):14-17. HU Sheng-yong,WANG Guo-li,LAI Sheng-jing,HOU Qiang,LIANG Tian-xi.Performances of Multilayered Damping Composite Panels within Five Years of Storage[J].Equipment Environmental Engineering,2017,14(1):14-17. |
多层阻尼复合板常温贮存5年性能研究 |
Performances of Multilayered Damping Composite Panels within Five Years of Storage |
投稿时间:2016-07-22 修订日期:2017-01-15 |
DOI:10.7643/ issn.1672-9242.2017.01.004 |
中文关键词: 多层阻尼复合板 贮存 正弦扫描试验 随机振动试验 |
英文关键词:multilayered damping composite panels storage sine scanning test random vibration test |
基金项目:中国工程物理研究院科学技术发展基金资助项目(2014B0203023) |
|
Author | Institution |
HU Sheng-yong | Institute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China |
WANG Guo-li | Institute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China |
LAI Sheng-jing | Institute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China |
HOU Qiang | Institute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China |
LIANG Tian-xi | Institute of Systems Engineering, China Academy of Engineering Physics, Mianyang 621999, China |
|
摘要点击次数: |
全文下载次数: |
中文摘要: |
目的 分析多层阻尼复合板常温贮存5年的性能变化。方法 对多层阻尼复合板进行常温下贮存5年的减振性能研究,通过贮存前后的正弦扫描试验和随机振动试验,获得贮存前后多层阻尼复合板的减振性能和模态变化,进行对比分析。结果 阻尼复合板常温贮存5年后,径向模态有较大的下降,法向模态变化较少,组件上的加速度响应基本无变化。结论 该多层阻尼复合板常温贮存5年后仍然满足要求。 |
英文摘要: |
Objective To analyze the performance change of multilayered damping composite panels after five years of storage. Method The vibration attenuation performance of multilayered damping composite panels was researched after five years of storage at normal atmospheric temperature. Vibration attenuation performance and modality variation of multilayered damping composite panels before and after storage were obtained according to sine scanning test and random vibration before and after storage to carry out contrastive analysis. Results After five years of storage, radial modality of panels declined obviously. The normal modality had little change. The acceleration response on subassemblies had no change. Conclusion Multilayered damping composite panels also meet the performance requests after five years of storage. |