陈建琼,唐其环,郭赞洪,杨晓然.海洋大气氯离子监测方法——湿烛法与干片法对比研究[J].装备环境工程,2017,14(6):77-83. CHEN Jian-qiong,TANG Qi-huan,GUO Zan-hong,YANG Xiao-ran.Comparative Study of Chlorides Deposition Rates Determination Methods in Marine Atmosphere—Wet Candle and Dry Plate Methods[J].Equipment Environmental Engineering,2017,14(6):77-83.
海洋大气氯离子监测方法——湿烛法与干片法对比研究
Comparative Study of Chlorides Deposition Rates Determination Methods in Marine Atmosphere—Wet Candle and Dry Plate Methods
投稿时间:2017-01-15  修订日期:2017-06-15
DOI:10.7643/ issn.1672-9242.2017.06.015
中文关键词:  湿烛法  干片法  ISO9225  氯离子沉降速率  气象因素
英文关键词:wet candle method  dry plate method  ISO9225  the Cl- deposition rate  meteorological factors
基金项目:
作者单位
陈建琼 西南技术工程研究所,重庆 400039 
唐其环 西南技术工程研究所,重庆 400039 
郭赞洪 西南技术工程研究所,重庆 400039 
杨晓然 西南技术工程研究所,重庆 400039 
AuthorInstitution
CHEN Jian-qiong Southwest Technology and Engineering Research Institute, Chongqing 400039, China 
TANG Qi-huan Southwest Technology and Engineering Research Institute, Chongqing 400039, China 
GUO Zan-hong Southwest Technology and Engineering Research Institute, Chongqing 400039, China 
YANG Xiao-ran Southwest Technology and Engineering Research Institute, Chongqing 400039, China 
摘要点击次数:
全文下载次数:
中文摘要:
      目的 对比研究两种海洋大气氯离子监测方法。方法 针对湿烛法与干片法各自的特点,在万宁试验站海洋平台、近海试验场、内试验场和不同离海距离的屋顶监测了两种方法多种条件下的氯离子沉降速率。采用成对数据的符号秩和检验法对比研究了湿润、透风、采样的方向性、氯离子污染程度对两种采样方法的监测结果的影响,采用皮尔逊积矩相关系数分析了气象因素对氯离子沉降速率的关系。结果 湿润、透风、采样的方向性是重要的影响因素,氯离子污染程度越大的环境,其影响程度越大。结论 诸多影响的综合结果导致了湿烛法监测的氯离子沉降速率高于干片法。
英文摘要:
      Objective To carry out comparative study of two kinds of chlorides deposition rates determination methods in marine atmosphere. Methods According to characteristics of wet candle and dry plate methods, Cl- deposition rate was monitored under various conditions by using the two methods in Wanning exposure station marine platform, offshore test site, inner test site and roofs of different distance away from the sea. Influences of humidity, ventilation, sampling orientation, chloride ion pollution degree on monitoring results of the two sampling methods were studied by using the signed rank of paired data and test method. The relationship between meteorological factors and Cl- deposition rate was analyzed by using Pearson product-moment correlation coefficient. Results Humidity, ventilation, sampling direction were important factors, and that the greater the degree of chloride pollution was, the greater the degree of influence. Conclusion The combined results of many effects lead to that the Cl- deposition rate of the wet candle method is higher than that of the dry plate method.