张亮,宋积文,陈胜利,王秀通,王润,臧寅.海洋石油平台导管架阴极保护监测数据分析与讨论[J].装备环境工程,2018,15(3):20-23. ZHANG Liang,SONG Ji-wen,CHEN Sheng-li,WANG Xiu-tong,WANG Run,ZANG Yin.Analysis and Discussion on Cathodic Protection Monitoring Data of Offshore Oil Platform Jacket[J].Equipment Environmental Engineering,2018,15(3):20-23. |
海洋石油平台导管架阴极保护监测数据分析与讨论 |
Analysis and Discussion on Cathodic Protection Monitoring Data of Offshore Oil Platform Jacket |
投稿时间:2017-11-14 修订日期:2018-03-15 |
DOI:10.7643/ issn.1672-9242.2018.03.004 |
中文关键词: 海洋石油平台 海洋腐蚀 阴极保护 腐蚀监测系统 |
英文关键词:offshore oil jacket platform marine corrosion cathodic protection corrosion monitoring system |
基金项目: |
|
Author | Institution |
ZHANG Liang | China National Offshore Oil Informtion Technology Beijing Branch, Beijing 100029, China |
SONG Ji-wen | China National Offshore Oil Informtion Technology Beijing Branch, Beijing 100029, China |
CHEN Sheng-li | China National Offshore Oil Informtion Technology Beijing Branch, Beijing 100029, China |
WANG Xiu-tong | Institutes of Oceanology, Chinese Academy of Sciences, Qingdao 266100, China |
WANG Run | China National Offshore Oil Informtion Technology Beijing Branch, Beijing 100029, China |
ZANG Yin | China National Offshore Oil Informtion Technology Beijing Branch, Beijing 100029, China |
|
摘要点击次数: |
全文下载次数: |
中文摘要: |
目的 研究海洋石油平台腐蚀现状,确保导管架处于阴极保护状态。方法 对近3年导管架阴极保护监测系统所采集的数据进行讨论,根据不同位置的电位电流传感器所获得的数据进行各个观测点位的腐蚀状态对比分析。结果 通过对数据研究表明,该系统电位电流传感器所采集的数据翔实可靠,所收集到的导管架节点电极电位均在保护范围内。就现阶段而言,导管架牺牲阳极输出电流基本趋于稳定。结论 该平台阴极保护监测设备运行良好,所测点位均处于阴极保护状态,且基本达到完全极化,对该海域新建平台防腐设计具有重要的参考价值。 |
英文摘要: |
Objective To study corrosion state of offshore oil jacket platform and ensure that the jacket is in the cathodic protection state. Methods The data in nearly three years obtained by the corrosion monitoring system were discussed. According to data obtained by the potential current sensor in the different places, corrosion state of each observation point was compared and analyzed. Results As the data research showed, the data collected by the potential current sensor this system was accurate and reliable. All electrode potential at node of jacket was in the range of protection. The output current of the sacrificial anode was stable in the current state. Conclusion The cathodic protection and monitoring system of the platform runs well. All of the measured points are protected and almost completely polarized. This result has an important reference value on the design and construction of offshore oil jacket platform. |