Study of Radiation Susceptibility Test Methods for Nuclear Power Plant Equipments
Received:October 26, 2011  
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:nuclear power plant equipments  I&C system  EMC
     
AuthorInstitution
LU Min 1. Shanghai Institute of Measurement and Testing Technology,Shanghai,China;2. Shanghai Key Laboratory of Electromagnetic Compatibility Testing,Shanghai,China
MA Xin 1. Shanghai Institute of Measurement and Testing Technology,Shanghai,China;2. Shanghai Key Laboratory of Electromagnetic Compatibility Testing,Shanghai,China
Hits:
Download times:
Abstract:
      The two standard systems MIL-STD and IEC were studied and compared, which were referred by USA nuclear regulatory commission (NRC) regulatory guide RG 1.180. The differences of MIL-STD and IEC in signal characteristic, testing layout, measurement method, and result analysis were discussed starting from RFI radiation susceptibility test. The technical details,result evaluation, and application methods were explained with examples. Technical suggestions on conducting the relevant tests were put forward. The purpose was to provide reference for EMC testing of nuclear power plant equipments.