Research on Method to Improve the Adaptability of Photoelectric Encoder in Hydrothermal Environment
Received:August 31, 2014  Revised:February 15, 2015
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2015.01.025
KeyWord:military electronic equipment  photoelectric encoder  hydrothermal environment  process improvement
  
AuthorInstitution
ZHAO Guang-wei The 29th Research Institute of CETC,Chengdu ,China
Hits:
Download times:
Abstract:
      Objective To study the methods to improve the adaptability of photoelectric encoder in hydrothermal environment. Methods This paper analyzed the causes for the low adaptability of photoelectric encoders in hydrothermal environment in a certain military electronic system, and then formulated some corresponding process improvement methods. Results According to the analysis, moisture entering into the photoelectric encoder and the joint of core wires was the cause for the high failure rate. This paper proposed the corresponding solution. As verified by the test results, no moisture entered the photoelectric encoder and the joint of core wires after implementation of the process improvement methods. Conclusion The new methods were verified to be effective by later experiments, and therefore the adaptability of photoelectric encoders in hydrothermal environment was greatly improved.
Close