A Method for Calculating Dew Point Temperature in the Humidity Test
Received:October 08, 2015  Revised:April 15, 2016
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2016.02.016
KeyWord:wet and dry bulb thermometer  saturation vapor pressure  dew point temperature  psychrometric handbook
        
AuthorInstitution
CHEN Xiao-chen Naval Aviation Military Agent′ s Room in Shenyang Area, Shenyang , China
ZHANG Qian Beihang University, Beijing , China
WU Sa Beihang University, Beijing , China
Hits:
Download times:
Abstract:
      Objective To study a method to set the dew point temperature as a control target in the climate environment test. Methods Wet and dry bulb thermometer was selected as the sensor to measure the vapor pressure, and the saturation vapor pressure was used as an important parameter to calculate the humidity, in order to explore an equation for calculating saturation vapor pressure applicable in micro-controller. Then a dew point temperature calculation model was established to obtain the relationship between the dew point temperature and vapor pressure. Results The values of 100 groups of samples in the range of 0-100℃ had small average error in comparison with the values in "Psychrometric Handbook". Conclusion This formula could be applied to calculate the dew point temperature in the humidity test.