Low Pressure Test Method of Pressure Switch
Received:July 18, 2016  Revised:January 15, 2017
View Full Text  View/Add Comment  Download reader
DOI:10.7643/ issn.1672-9242.2017.01.010
KeyWord:tethered balloon  pressure switch  low pressure test
        
AuthorInstitution
CHEN Chang-hui China Special Vehicle Research Institute, Jingmen , China
PANG Cheng-long China Special Vehicle Research Institute, Jingmen , China
LI Jin China Special Vehicle Research Institute, Jingmen , China
Hits:
Download times:
Abstract:
      Objective To improve the qualified rate of pressure switch in low pressure test. Methods Low pressure test methods of pressure switches to be used to tethered balloons were researched. Defects of traditional low pressure test methods were analyzed and a new low pressure test method was proposed. Contrast test on two test methods were carried out. Results The pass rate of pressure switches was 40% when the test was carried according to the traditional method. The new low pressure test method could improve the pass rate of pressure switches significantly. Conclusion The new low pressure test method can improve the pass rate of pressure switches and reflect actual conditions of pressure switches more objectively.