Marine Climate Environmental adaptability of Aircraft Electrical Wiring Interconnection System
Received:October 25, 2018  Revised:April 25, 2019
View Full Text  View/Add Comment  Download reader
DOI:10.7643/ issn.1672-9242.2019.04.008
KeyWord:electrical wiring interconnection system  marine climate environment  environmental adaptability  corrosion prevention
              
AuthorInstitution
YU Da-zhao 1. School of Basic Science for Aviation, Naval Aviation University, Yantai , China
WEN De-hong 2. Aeronautical Equipment Department of Naval Equipment Department, Beijing , China
WANG Lin 1. School of Basic Science for Aviation, Naval Aviation University, Yantai , China
WANG Teng 1. School of Basic Science for Aviation, Naval Aviation University, Yantai , China
WANG Si-huan 1. School of Basic Science for Aviation, Naval Aviation University, Yantai , China
Hits:
Download times:
Abstract:
      Based on fault results of the Electrical Wiring Interconnection System (EWIS) and the South China Sea environ-mental exposure test results of the aircraft's typical Electrical Wiring Interconnection System (EWIS), the corrosion failure law, corrosion types and causes, and electrical performance variation law of EWIS in marine environment were studied. The results show that the failure modes of EWIS corrosion in marine environment were various, which can easily lead to frequent intermittent faults and decrease of electrical performance and shielding effectiveness. From the point of view of seaworthiness, it is proposed to improve the marine environmental adaptability of EWIS from material selection, design, operation and maintenance, and analysis and utilization of fault data.
Close