Dynamic Characteristics of a Certain Servo Oil Drain Pipe
Received:September 28, 2018  Revised:July 25, 2019
View Full Text  View/Add Comment  Download reader
DOI:10.7643/ issn.1672-9242.2019.07.023
KeyWord:servo oil drain pipe  dynamic characteristics  finite element simulation
              
AuthorInstitution
YU Shao-ming Beijing Institute of Structure and Environment Engineering, Beijing , China
ZHAO Shuai-shuai Beijing Institute of Structure and Environment Engineering, Beijing , China
ZHU Yi-fan Beijing Institute of Structure and Environment Engineering, Beijing , China
CHEN Di-Kui Beijing Institute of Structure and Environment Engineering, Beijing , China
LU Yong Beijing Institute of Structure and Environment Engineering, Beijing , China
Hits:
Download times:
Abstract:
      Objective To provide a basis for the determination of pipeline design scheme by studying the dynamic character-istics of a certain type of servo oil drain pipe. Methods Vibration tests of three design schemes of servo oil drainage pipes were carried out to measure the strain response at key positions. The results were analyzed by the finite element method. Results The resonance frequency of the servo exhaust pipe was near 180 Hz. When there was a peak value near 180 Hz, the coupling resonance would occur and the strain of the pipeline was very large. Conclusion In pipeline design, the resonance frequency should avoid the dangerous frequency of environment, and the pipeline should be strengthened when it can not be avoided.