Simulation Study on Corrosion Related Electromagnetic Field of Ship |
Received:July 18, 2010 Revised:February 15, 2011 |
View Full Text View/Add Comment Download reader |
DOI: |
KeyWord:ship corrosion related electromagnetic field cathodic protection computer simulation |
Author | Institution |
LU Lu |
State Key Laboratory for Marine Corrosion and Protection,Luoyang Ship Material Research Institute,Qingdao ,China |
XING Shao-hua |
State Key Laboratory for Marine Corrosion and Protection,Luoyang Ship Material Research Institute,Qingdao ,China |
YAN Yong-gui |
State Key Laboratory for Marine Corrosion and Protection,Luoyang Ship Material Research Institute,Qingdao ,China |
WU Jian-hua |
State Key Laboratory for Marine Corrosion and Protection,Luoyang Ship Material Research Institute,Qingdao ,China |
|
Hits: |
Download times: |
Abstract: |
Due to development of electromagnetic field detection technology and application of intelligent mine, corrosion related electromagnetic field has serious influence on stealth and safety of ship. In order to comparatively study the characteristics of electromagnetic field when there was no cathodic protection, the ship was protected by impressed current cathodic protection and sacrificial anode respectively. Computer simulation technology was tentatively used to calculate the strength of electric and magnetic field. Simulation results showed that corrosion related electromagnetic field has its own unique characteristics, and the electromagnetic field induced by impressed current cathodic protection was the strongest one, and the electromagnetic field induced by sacrificial anode was stronger than that when there was no cathodic protection. |
Close |