Ship Shaft-frequency Electric Field Testing Based on Harmonic Waves Adaptive Line Enhancer
Received:August 20, 2010  Revised:April 15, 2011
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:Shaft-frequency electric field  harmonic waves  adaptive line enhancer
           
AuthorInstitution
LIU Yan-qiong No. 760 Research Institute of CSIC, Dalian ,China
YUE Rui-yong No. 760 Research Institute of CSIC, Dalian ,China
TIAN Zuo-xi No. 760 Research Institute of CSIC, Dalian ,China
HAN Jing No. 760 Research Institute of CSIC, Dalian ,China
Hits:
Download times:
Abstract:
      Shaft-frequency electric field of ship exists in 1~7 Hz and it has obvious harmonic waves. For these characteristics, harmonic waves adaptive line enhancer technology was applied to signal processing of the shaft-frequency electric field of a ship. Correlative parameters were determined through simulation. This method was used in measurement signal. The power spectrum intensity of line spectrum increased by 0.056 μ v/m higher than continuous spectrum. It was proved that background noise can be restrained effectively in shaft-frequency electric field signal with this method.