Measurement and Comparison of Cathodic Protection Potential of Different Sacrificial Anode Material
Received:November 05, 2010  Revised:June 15, 2011
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:body potential  sacrificial anode  polarization rapidity
              
AuthorInstitution
HUANG Yan-bin Department of Equipment Remanufacture Engineering,Academy of Armored Force Engineering,Beijing ,China
SONG Gao-wei Department of Equipment Remanufacture Engineering,Academy of Armored Force Engineering,Beijing ,China
DING Hua-dong Department of Equipment Remanufacture Engineering,Academy of Armored Force Engineering,Beijing ,China
LIU Xue-bin Department of Equipment Remanufacture Engineering,Academy of Armored Force Engineering,Beijing ,China
BIAN Fei-long Department of Equipment Remanufacture Engineering,Academy of Armored Force Engineering,Beijing ,China
Hits:
Download times:
Abstract:
      Body potential of amphibian vehicle with different sacrificial anode material was measured with continuous measure method. It was proved by measuring data that quinary and hexahydroxy alloy anode both cannot provide enough protection potential for amphibian vehicle; the polarization rapidity of quinary alloy anode is slower than hexahydroxy one; The hexahydroxy anode is suited for amphibian vehicles better.