Study on Design of Wire-on-bolt Test Specimen Parameter |
Received:December 04, 2011 Revised:August 15, 2012 |
View Full Text View/Add Comment Download reader |
DOI: |
KeyWord:WOB test contrast test atmosphere corrosion |
Author | Institution |
LIU Cong |
1. No.59 Research Institute of China Ordnance Industry, Chongqing , China;2. The Engineering and Technology Center of Environmental Corrosion and Protection of Chongqing, Chongqing , China |
LIU Bin |
PLA Military Representatives of 296 Factory, Chongqing , China |
TANG Qi-huan |
1. No.59 Research Institute of China Ordnance Industry, Chongqing , China;2. The Engineering and Technology Center of Environmental Corrosion and Protection of Chongqing, Chongqing , China |
LI Di-fan |
1. No.59 Research Institute of China Ordnance Industry, Chongqing , China;2. The Engineering and Technology Center of Environmental Corrosion and Protection of Chongqing, Chongqing , China |
|
Hits: |
Download times: |
Abstract: |
Wire-on-bolt technology is a kind of fast evaluation technology for atmospheric corrosivity. Appropriate design of specimen parameter is an important problem of Wire-on-bolt technology study. Specimen parameters′ influence on wire corrosion rate was analyzed by atmosphere exposure test of specimens in different parameters. It was concluded that the proper parameter is that galvanic couple material of test specimen is T2 copper and 1100 aluminum; the copper bolt is M25 × 6; and dimension of aluminum wire is 3mm diameter and 1m length. |
Close |