A Method of Increasing Airtight Function of Hard Chromium Plating
Received:May 07, 2012  Revised:August 15, 2012
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:airtight function  hard chromium plating  sealing-treatment
                 
AuthorInstitution
TANG Zhi-hui Beijing Institute of Aeronautical Materials, Beijing , China
WANG Chang-liang Beijing Institute of Aeronautical Materials, Beijing , China
WANG Li-qiang Chengdu Aircraft Industrial(Group)Co. Ltd., Chengdu , China
DAI Shu-cheng Chengdu Aircraft Industrial(Group)Co. Ltd., Chengdu , China
YUE Wen-hua Beijing Institute of Aeronautical Materials, Beijing , China
LU Feng Beijing Institute of Aeronautical Materials, Beijing , China
Hits:
Download times:
Abstract:
      The causes of poor airtight performance of hard chromium plaiting were analyzed. A sealing-treatment was employed in the post-treatment of hard chromium plaiting to improve the airtight function of the coating system. The results showed that the hard chromium plaiting passes 20 MPa/30 min airtight function testing with no leakage of gas after the post-treatment by 518 sealing reagent; the sealing reagent penetrates as deep as 20~30 μm and co-operates well with hydraulic fluid.