Study on Corrosion-resistant Performance of Different Welded Joints of B610E in the Deposited Water of Petroleum |
Received:August 16, 2012 Revised:December 15, 2012 |
View Full Text View/Add Comment Download reader |
DOI: |
KeyWord:deposited water corrosion welding joint B610E tank steel |
Author | Institution |
JIA Si-yang |
1. Qingdao NCS Testing & Corrosion Protection Technology Co., Ltd., Qingdao , China;2. Qingdao Marine Corrosion Institute of Central Research Institute of Iron and Steel, Qingdao , China |
LI Chao |
1. Qingdao NCS Testing & Corrosion Protection Technology Co., Ltd., Qingdao , China;2. Qingdao Marine Corrosion Institute of Central Research Institute of Iron and Steel, Qingdao , China |
HAN Dong-rui |
1. Qingdao NCS Testing & Corrosion Protection Technology Co., Ltd., Qingdao , China;2. Qingdao Marine Corrosion Institute of Central Research Institute of Iron and Steel, Qingdao , China |
|
Hits: |
Download times: |
Abstract: |
The corrosion-resistant performance of different welded joints of B610E high-strength tank steel in the deposited water of petroleum was investigated by indoor soaking test, and stress corrosion test. Results showed that B610E gas shielded welding materials has the best corrosion-resistance; submerged arc welding of Q235+B610E pairing is the worst due to galvanic corrosion effect; in the deposited water of petroleum, B610E submerged horizontal welding with medium resistance to SCC; B610E gas shielded welding, B610E electro-gas welding and B610E+Q235 submerged flat welding has high SCC resistance. |