Sealing Performance Analysis of Sealing Element in the Floor Sealing Structure of Refueling Pool in Nuclear Power Plant
Received:October 21, 2013  Revised:December 15, 2013
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2014.02.021
KeyWord:floor sealing structure of refueling pool  sealing component  finite element  preloaded fore  deformation
     
AuthorInstitution
WENG Na Shanghai Nuclear Engineering Research and Design Institute, Shanghai, China
XU Feng Shanghai Nuclear Engineering Research and Design Institute, Shanghai, China
Hits:
Download times:
Abstract:
      ObjectiveTo study the sealing performance of the floor sealing structure of the refueling pool in a nuclear power plant.MethodsAn axial-symmetry finite element model of the sealing component using super elastic element was built by ANSYS. Then the contact surface of the sealing structure was simulated by the contact element.ResultsA curve between preloaded force and deformation was calculated.ConclusionThe results can be used to solve the test leakage problem of the floor sealing structure of refueling pool and could also be used as a reference in getting preloaded force of sealing components.
Close