Loop Antenna Calibration Technology Based on SAE-ARP958 |
Received:September 15, 2015 Revised:February 15, 2016 |
View Full Text View/Add Comment Download reader |
DOI:10.7643/issn.1672-9242.2016.01.023 |
KeyWord:calibration device SAE-ARP958 electromagnetic environment |
Author | Institution |
GAO Gang |
723 Institute of China Shipbuilding Industry Corporation, Yangzhou , China |
ZHU Yi-sheng |
723 Institute of China Shipbuilding Industry Corporation, Yangzhou , China |
|
Hits: |
Download times: |
Abstract: |
Objective To introduce the loop antenna calibration technology based on the SAE-ARP958 and investigate the method improving the accuracy of the calibration,which guarantees accurate monitoring in electromagnetic environment. Methods The design of a set of loop antenna calibration based on the SAE-ARP958 was proposed, the calibration scheme of using three launch loop antennas with the respective diameter of 30 cm, 10 cm and 4 cm as the magnetic field generator was put forward, and the method of comparison test was used for optimization of the calibration scheme. Results The optimized calibration scheme can realize accurate loop antenna calibration. Conclusion Loop antenna calibration method based on the SAE-ARP958 has the advantage of not being restricted to loop antenna size, and the accuracy is high, which is worth to be prompted to the users with different loop antenna sizes. |