Galvanic Corrosion Model with Insulation Spacer
Received:November 08, 2016  Revised:February 15, 2017
View Full Text  View/Add Comment  Download reader
DOI:10.7643/ issn.1672-9242.2017.02.012
KeyWord:galvanic corrosion  insulation spacer  electrochemistry model
           
AuthorInstitution
ZHOU Zi-long Naval University of Engineering, Wuhan , China
ZHANG Lei Naval University of Engineering, Wuhan , China
HU Hui-e Naval University of Engineering, Wuhan , China
LIU Ming-guang Service College of Naval University of Engineering, Tianjin , China
Hits:
Download times:
Abstract:
      Objective To design a galvanic corrosion model with insulation spacer and test the isolation effect. Methods Three kinds of materials, such as pipeline sealing gasket, non-woven fabrics and sealing daub were selected as spacer to test galvanic current, galvanic voltage and electrochemical alternating-current impedance. Results The galvanic current of sealing daub was the smallest. Its electrochemical impedance was always high; non-woven fabric was easy to be wetted, so it had the largest electric current; but it had the highest dry insulation resistance also. Conclusion The galvanic corrosion model designed is feasible. The result of different electrochemical methods are corresponding, improving the credible degree of the result. The effect of material isolation is related to the wetting degree of medium, and has little relationship with its dry insulation resistance.