Monitoring of Micro Salt Fog in Storage Environment of a System
Received:August 30, 2017  Revised:October 15, 2017
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2017.10.015
KeyWord:salt fog concentration  deposition rate  monitoring method
        
AuthorInstitution
MA Chang-li Naval Academy, Beijing , China
LIU Cong Southwest Technology and Engineering Research Institute, Chongqing , China
MA Rui-ping Naval Academy, Beijing , China
Hits:
Download times:
Abstract:
      Objective To monitor the micro salt fog in a system's storage environment and determine its salt fog pollution level. Methods According to the two indexes of salt fog concentration and salt fog deposition rate, the current monitoring and analysis methods were summarized and compared. According to the characteristics of a system's storage environment, monitoring plans were formulated and field monitoring was carried out. Results The salt fog value of area C in a system was higher than that in areas A and B. Conclusion The measured salt fog concentration in the storage environment of the system is 1-2 orders of magnitude lower than that required. The salt fog pollution is the lowest S0 level.