Failure of Spring Pressure Gage and Mercury Corrosion in Gas Field
Received:August 17, 2017  Revised:December 15, 2017
View Full Text  View/Add Comment  Download reader
DOI:10.7643/ issn.1672-9242.2017.12.001
KeyWord:spring pressure gage  leaking  mercury  corrosion  gas field
                 
AuthorInstitution
LIN Guan-fa Tubular Goods Research Institute, CNPC, Xi'an , China
WANG Jun-qi Tarim Oilfield Company, CNPC, Korla , China
MA Jin-long Tarim Oilfield Company, CNPC, Korla , China
SONG Cheng-li Tubular Goods Research Institute, CNPC, Xi'an , China
DING Han Tarim Oilfield Company, CNPC, Korla , China
LI Lei Tubular Goods Research Institute, CNPC, Xi'an , China
Hits:
Download times:
Abstract:
      Objective To analyze causes for leaking of spring tube of pressure gage based on leaking of pressure gage of certain gas field. Methods The inner structure and surface damage of spring tube were observed, and the damage regions were detected with permeating method of nondestructive testing, metallographic microscope, scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). Results There was a penetrative crack extending along the crystal in the tube. The mercury element and a bit of CO2 corrosion product were detected in the mixing region between and on the crystal grains. Conclusion The leaking of spring tube in the pressure gage is resulted from the mercury corrosion that the Al and Cu elements in the spring tube made from Monel alloy formed amalgam with Hg in the gas and the cracking of the tube under the inner pressure action.