Comparison and Analysis of Results of Copper Alloy Laboratory Test and Real Sea Hanging Sheet
Received:February 08, 2018  Revised:May 25, 2018
View Full Text  View/Add Comment  Download reader
DOI:10.7643/ issn.1672-9242.2018.05.009
KeyWord:copper alloys  linear polarization  electrochemical impedance  corrosion in seawater  microscopic analysis
        
AuthorInstitution
ZHOU Peng-fei Foundation Department, Navy University of Engineering, Wuhan , China
KONG Xiao-dong Foundation Department, Navy University of Engineering, Wuhan , China
SU Xiao-hong Foundation Department, Navy University of Engineering, Wuhan , China
Hits:
Download times:
Abstract:
      Objective To compare the similarities and differences between results of laboratory simulation and real sea hanging sheet to evaluate the corrosion performance of the two copper alloys. Methods Certain tests such as linear polarization, electrochemical impedance and microstructure analysis were carried out to compare corrosion rate, pitting corrosion tendency, reaction mechanism, corrosion morphology, environment and other external factors of the two kinds of copper alloys in simulated seawater. Results Except Yulin sea area, both the real sea hanging tablets and the laboratory results show that the average corrosion rate of B10 was less than that of H62. The corrosion rate of B10 and H62 were consistent with the increase of temperature; and the average corrosion rate decreased with the increase of immersion time. Conclusion In the practical environment, the temperature is not the main factor which influences the pitting. Microorganisms and other environmental factors have great influence on the pitting.