Design and Performance Test of Pipeline Erosion-corrosion Apparatus
Received:June 26, 2019  Revised:September 03, 2019
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2019.12.009
KeyWord:erosion-corrosion  structure design  control system  corrosion mechanism
              
AuthorInstitution
WANG Kun College of Mechanical and Power Engineering, Guangdong Ocean University, Zhanjiang , China
WU Jing-quan College of Mechanical and Power Engineering, Guangdong Ocean University, Zhanjiang , China
DENG Pei-chang College of Mechanical and Power Engineering, Guangdong Ocean University, Zhanjiang , China
WANG Gui College of Mechanical and Power Engineering, Guangdong Ocean University, Zhanjiang , China
HU Jie-zhen College of Mechanical and Power Engineering, Guangdong Ocean University, Zhanjiang , China
Hits:
Download times:
Abstract:
      Objective To accelerate the corrosion of pipeline inner wall, study the influence of corrosion factors on corrosion mechanism and corrosion behavior of pipeline inner wall, and design a pipeline erosion-corrosion apparatus independently. Methods The apparatus belongs to mechatronics product which includes the overall structure design as well as hardware design and software design of the control system. PLC was used as the central processing unit and touch screen was used as the man-machine interface in the control system. The temperature and flow rate of corrosion factors were regulated. In addition, the performance of the device was tested. Results The control precision of temperature could be -0.5℃ to +0.8℃; and the control precision of flow velocity could reach ±0.01m/s. Conclusion The device has reliable operation, wide testing range and good performance, which establishes the experimental foundation for studying the erosion-corrosion of pipeline.
Close