Failure Analysis and Laboratory Study of Zinc Anode in Ballast Tank
Received:March 20, 2020  Revised:April 20, 2020
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2020.10.010
KeyWord:FPSO  ballast tank  zinc anode  failure  experimental study
           
AuthorInstitution
ZHU Fei-yue Offshore Oil Engineering Co., Ltd, Tianjin , China
ZHANG Guo-qing Offshore Oil Engineering Co., Ltd, Tianjin , China
LYU Jian-wei Offshore Oil Engineering Co., Ltd, Tianjin , China
SONG Bo Offshore Oil Engineering Co., Ltd, Tianjin , China
Hits:
Download times:
Abstract:
      The work aims to find out the cause for failure of zinc anode in ballast tank and put forward the repair plan. The service environment was investigated, the chemical composition of anode was tested, the electrochemical properties were inspected and the surface morphology was detected. The dry-wet alternating environment and high temperature were main causes for passivation of zinc anode. Under dry-wet alternating environment, the grains on the corroded surface of anode were loose, the width of grain boundary was large and the intergranular corrosion and grain shedding occurred, resulting in anode failure. Through the experimental study of this project, the applicable conditions of zinc anode are obtained. In the dry-wet alternating environment and at high temperature (50 ℃), aluminum anode instead of zinc anode is recommended.