Analysis on Application of Electric Insulation Testing of Cathodically Protected Underground Steel Pipelines
Received:December 07, 2020  Revised:December 29, 2020
View Full Text  View/Add Comment  Download reader
DOI:10.7643/issn.1672-9242.2021.04.004
KeyWord:cathodic protection  electric insulation, current leakage rate  insulating joint  current leakage  current loop
              
AuthorInstitution
CHEN Zhen-hua Pipe China North Pipline Co.Ltd R & D Center, Langfang , China
CHENG Yu-kui Hebei Anke Engineering and Technology Co.Ltd., Shijiazhuang , China
GAO Jun-tao Hebei Anke Engineering and Technology Co.Ltd., Shijiazhuang , China
MAN Xiu-qing Hebei Anke Engineering and Technology Co.Ltd., Shijiazhuang , China
XIE Xiao-bo Northeastern Petroleum Pipeline Co.Ltd., Shenyang , China
Hits:
Download times:
Abstract:
      The paper based on electric insulation testing in eighty oil &gas stations and valve chests of cathodically protected buried steel pipelines to introduce the status and characteristic of electric insulation fault in Cathodic protection system, and the usability and application conditions of normal inspection methods for electric insulation troubleshooting. Depending on the actual testing data and electrical simulation model, the errors as well as the cause in some testing methods, such as potential measurement, current leakage rate measurement, have been analyzed. Moreover, the characteristic and performance of external lap, conducting medium deposition and insulation device failure, focused on these three typical electric insulation fault, the specific troubleshooting methods have been recommend, which could be useful for inspector to locate the fault quickly and accurately.